Technical Specifications of the BIKAI UHPLC System
The BIKAI 1521 UHPLC and 1511 2D systems share one high-pressure platform. These are the core specifications.
| System Capabilities and Performance Data | |
|---|---|
| System Type | Ultra High Performance Liquid Chromatography (UHPLC) and 2D UHPLC |
| Max. Operating Pressure | 16,000 PSI (110 MPa, 1,100 bar) at 0 to 2 mL/min |
| Pump (Binary) | UP25 ultra high pressure binary gradient pump |
| Autosampler | A65 ultra high pressure (max 18,000 PSI), 100 µL loop |
| Autosampler Capacity | High throughput: up to 216 positions of 1.5 mL vials, or 4 x 96-well plates |
| Detector Options | D25 and D26 diode array detectors (DAD/PDA) |
| Wavelength Range | 190 nm to 640 nm (D25) | 190 nm to 800 nm (D26) |
| Flow Rate Range | 0.001 mL/min to 10.000 mL/min |
| Software Platform | EyouLab Enterprise, fully networkable, FDA 21 CFR Part 11 compliant |
UHPLC vs HPLC: Key Benefits and Differences
The main differences between UHPLC and HPLC are pressure limit, speed and resolving power.
| Factor | BIKAI UHPLC (1521) | BIKAI HPLC (1511) |
|---|---|---|
| Max. pressure | 16,000 PSI (1,100 bar) | 10,500 PSI |
| Column particles | Sub-2-micron | Conventional |
| Speed and resolution | Faster runs, higher resolution | Suited to conventional analysis |
| Best for | High throughput, complex separations | Routine QC and general analysis |
Compare configurations on the BIKAI HPLC system page.
- Pressure Tolerance for Finer ParticlesWithstand 16,000 PSI (1,100 bar) and use sub-2-micron particle columns to improve peak resolution beyond what standard HPLC allows.
- High Speed, Shorter Run TimesHigher pressure allows a higher mobile phase linear velocity without losing efficiency, so the UHPLC processes more samples per hour and uses less solvent.
- Ultra-Low Dispersion DetectorsThe D25 and D26 diode array detectors use optimized total reflection flow cells that reduce extra-column volume for sensitive trace compound detection.
- 2D UHPLC CapabilityThe 1511 2D UHPLC integrates dual-dimensional separation for complex matrices, improving productivity and reducing extensive sample pre-treatment.
- 21 CFR Part 11 Compliant SoftwareEyouLab Enterprise supports audit trails, system suitability tests (SST) and tiered user access for GMP and GLP labs.
UHPLC Applications: What Is a UHPLC System Used For?
- Pharmaceutical AnalysisStability-indicating API assays, rapid impurity profiling, and high-throughput drug testing and validation in FDA and GMP environments.
- Food Testing and Chemical AnalysisIdentify trace-level pesticides, mycotoxins and complex additives in food matrices where peak overlap is a problem.
- Research and BiotechnologySupport proteomics and metabolomics work, and biological compound isolation with 2D UHPLC methods.
How UHPLC Works
- Load samples into the A65 autosampler (up to 216 vials or 4 x 96-well plates).
- Pump the mobile phase with the UP25 binary gradient pump at pressures up to 16,000 PSI.
- Separate on a sub-2-micron column for high resolution in short run times.
- Detect compounds with the D25 or D26 diode array detector.
- Process and report in EyouLab Enterprise with a full audit trail.