Gas Chromatography System Price in India | BIKAI GC 2000 with FID, ECD, FPD
BIKAI GC 2000 gas chromatography system with FID, ECD and FPD detectors and 8-inch Android touch screen
Advanced Gas Chromatography Equipment
Category: Laboratory Analytical Instruments

BIKAI GC 2000 Gas Chromatography System | GC Instrument with FID, ECD, FPD

4.8 out of 5 from 38 reviews

The BIKAI GC 2000 is a gas chromatograph with electronic pressure control (0.001 psi precision), a 450°C column oven, split/splitless injection and an 8-inch Android touch screen. It holds up to 4 detectors (FID, ECD, FPD) and 2 injection ports for pharmaceutical, food safety, environmental and petrochemical analysis.

If you want to buy a gas chromatography system in India, the GC 2000 delivers reproducible GC analysis with an electronic flow pressure control module, automatic leak check and software-based self-diagnosis. Peak area repeatability is under 0.5% and retention time repeatability is under 0.008%.

  • 8-Inch Android Touch Screen
  • Split/Splitless Injection
  • Ultra-High EPC Precision
Android Touch
Screen Software
0.001 psi
Electronic Control
450°C Column
Oven
FID, ECD &
FPD Detectors
Split/Splitless
Injection Ports

Designed as a highly programmable gas chromatograph, the system accepts up to 4 detectors and 2 injection ports at the same time. Choose a high sensitivity FID detector, an ECD detector for trace halogens or an FPD detector for sulfur and phosphorus compounds. This laboratory gas chromatography unit adapts to pharmaceutical, food safety, environmental and petrochemical workflows.

BIKAI GC 2000 Gas Chromatography System Specifications

BIKAI GC 2000 technical specifications
Analytical Capabilities and GC System Components
Main System and Injection
Brand / ModelBIKAI GC 2000
System ControlElectronic pressure control (EPC), 0.001 psi precision, programmed pressure rise and flow rise up to fourth order
Injection PortsUltra-deactivated split/splitless port (up to 2 installed)
Split RatioUp to 12500:1
Carrier Gas SupportAr, N2, He and H2
RepeatabilityPeak area under 0.5%; retention time under 0.008%
Column Oven Parameters
Temperature RangeRoom temperature +4°C to 450°C
Heating / Cooling RateMax heating 120°C/min; cooling from 450°C to 50°C in 6 minutes
Heating Programs32 oven heating gradients and 33 constant temperature platforms
Gas Chromatography Detectors
FID DetectorBaseline noise <1x10-13 A | Detection limit <1.2x10-12 g C/s
ECD Detector63Ni radioactive source | Baseline noise <0.02 mV | Linear range 104
FPD DetectorSingle wavelength detector for sulfur and phosphorus compound analysis
Interface and Dimensions
User Interface8-inch Android capacitive touch screen
Dimensions / Weight486 mm (H) x 556.4 mm (W) x 558 mm (D) | 38.1 kg

Advantages of the BIKAI GC 2000 System

  • ✓
    Android Touch Screen and Self-DiagnosisCustomized Android host control software on a GC with touch screen runs an automatic leak check before each analytical run, with built-in self-diagnosis and self-leakage detection.
  • ✓
    High Precision Electronic Pressure Control (EPC)An electronic pressure control gas chromatograph module with ruby damping approaches 0.001 psi accuracy and supports programmed pressure rise and flow rise up to fourth order.
  • ✓
    Multiple Detectors on One InstrumentInstall up to 4 detectors and 2 injection ports simultaneously and run GC-FID, GC-ECD and GC-FPD workflows on a single footprint.
  • ✓
    Ultra-Deactivated Injection PortsThe split/splitless injection port removes active surface sites, improving sensitivity and peak shape for trace active substances. Electronic septum purge flow control eliminates ghost peaks.
  • ✓
    Fast Oven Cooling and Flexible ProgrammingCool from 450°C to 50°C in 6 minutes and program up to 32 heating gradients for faster sample turnaround.

Gas Chromatography Applications by Industry

  • ✓
    Pharmaceutical Lab: Residual Solvents and Volatile ImpuritiesAnalyze volatile impurities, active pharmaceutical ingredients and residual solvents in line with modern pharmacopoeia standards.
  • ✓
    Food Testing and Pesticide Residue AnalysisUse the ECD for pesticide residue testing, halogenated pollutants and agricultural chemical residues in food safety and environmental labs.
  • ✓
    Petrochemical and Environmental LabsTrack trace sulfur and phosphorus compounds with the FPD, and hydrocarbons with the FID, in oil, gas and complex petrochemical matrices.

FID vs ECD vs FPD: Which GC Detector Do You Need?

Comparison of FID, ECD and FPD gas chromatography detectors
DetectorDetectsTypical use
FID (Flame Ionization)Hydrocarbon-containing compoundsResidual solvents, hydrocarbons, general organic analysis
ECD (Electron Capture)Electronegative compounds such as halogensHalogenated pesticides, environmental pollutants
FPD (Flame Photometric)Sulfur and phosphorus compoundsPetrochemicals, organophosphorus compounds

How Gas Chromatography Works

  1. Inject the sample through the split/splitless port, where it is vaporized.
  2. Carry it through the column with the carrier gas (He, N2, H2 or Ar) under electronic pressure control.
  3. Separate the components as the column oven follows your temperature program.
  4. Detect each compound with the FID, ECD or FPD.
  5. Identify and quantify peaks by retention time and peak area.

Explore Related Laboratory Instruments

Gas Chromatography System FAQs

What is a gas chromatography system used for in laboratory analysis?
A gas chromatography system separates, identifies and quantifies compounds that can be vaporized without decomposition. It is used for residual solvent testing, volatile impurities, pesticide residue analysis, food safety and environmental analysis.
What is the difference between FID, ECD and FPD detectors in gas chromatography?
The FID measures hydrocarbon-containing compounds and is the most common universal detector. The ECD (with a 63Ni source) is highly sensitive to electronegative compounds such as halogenated pesticides. The FPD is specialized for sulfur and phosphorus compounds.
What is electronic pressure control (EPC) in a gas chromatography system?
EPC digitizes gas flow control. Software adjusts carrier and makeup gases instead of manual valves. The GC 2000 offers 0.001 psi precision, programmed pressure rise and flow rise up to the fourth order, and pressure and temperature compensation so lab conditions do not affect results.
What is the column oven temperature range of the BIKAI GC 2000?
The column oven runs from room temperature +4°C to 450°C with a maximum heating rate of 120°C per minute, 32 heating gradients and 33 constant temperature platforms. It cools from 450°C to 50°C in 6 minutes.
How many detectors and injection ports can the GC 2000 hold?
The GC 2000 supports up to 4 detectors and 2 injection ports installed simultaneously, so FID, ECD and FPD workflows can run on one instrument.
What is the price of a gas chromatography system in India?
The price depends on the chosen detectors (FID, ECD, FPD) and configuration. Global Bioscience Solutions, an analytical instrument supplier in Bangalore, provides a customized GST quotation. Use the quote form or WhatsApp for pricing, delivery and support.