Authorized Blue-Ray Biotech Distributor in India
Category: Spectrophotometers · Blue-Ray Biotech

EzDrop 1000C Micro-Volume & Cuvette Spectrophotometer

4.9 / 5 based on 32 customer reviews

The Blue-Ray EzDrop 1000C is a dual mode spectrophotometer that pairs a 1 µL microvolume pedestal with a heated, stirred cuvette port (37, 40 and 45°C). It covers 190–1000 nm and reads in under 3 seconds.

A versatile NanoDrop alternative with cuvette, it handles nucleic acid quantification, protein assays, OD600 and enzyme kinetics in one standalone touchscreen unit, supplied and supported from Bengaluru by Global Bioscience Solutions.

✓ Dual measurement modes   ✓ 37–45°C temperature control   ✓ Built-in stirring

Dual Mode: Drop & Cuvette
37–45°C Heating
Built-In Stirrer
1 µL Low Sample Volume
Standalone Touchscreen

EzDrop 1000C at a Glance

The EzDrop 1000C is a dual mode UV-Vis spectrophotometer made by Blue-Ray Biotech and supplied in India by Global Bioscience Solutions (Bengaluru). Microvolume mode quantifies DNA, RNA and protein from 1–2 µL, while cuvette mode adds 37/40/45°C heating, stirring and kinetics for incubated protein assays, OD600 and enzyme studies. It covers 190–1000 nm, reads in under 3 seconds and runs standalone on a 7-inch touchscreen.

Technical Specifications: EzDrop 1000C

A compact laboratory spectrophotometer built for both static DNA readings and dynamic, temperature-dependent assays. For microvolume-only work see the EzDrop 1000.

Blue-Ray EzDrop 1000C performance data
Measurement ModesDual mode: micro-volume (1–2 µL) and cuvette
Wavelength Range190–1000 nm (full UV-Vis)
Cuvette Temperature Control37°C, 40°C, 45°C (built-in heater)
Cuvette StirringBuilt-in stir function
Microvolume Pathlength0.5 mm and 0.05 mm
Absorbance Accuracy1% at 260 nm
Detection Range (dsDNA)2–25,000 ng/µL
Detection Range (BSA)0.06–750 mg/mL
OD Range0.02–500 A (10 mm equivalent)
Measurement TimeUnder 3 seconds
User Interface7-inch color capacitive touchscreen; standalone or PC-connected
Brand / SupplierBlue-Ray Biotech / Global Bioscience Solutions, India

Full details are in the official EzDrop 1000/1000C operation manual.

EzDrop 1000C vs EzDrop 1000 vs Cuvette UV-Vis

FeatureEzDrop 1000CEzDrop 1000Cuvette UV-Vis
Microvolume (1–2 µL)YesYesNo
Cuvette modeYesNoYes
Heating (37/40/45°C)YesNoModel dependent
Stirring and kineticsYesNoModel dependent
Best forMicro + incubated/kinetic assaysPrecious DNA/RNA/proteinRoutine bulk assays

Key Innovations of the EzDrop 1000C

  • ✓

    37–45°C Cuvette Temperature Control

    The integrated cuvette port is heated, making this a true heated cuvette spectrophotometer for temperature-dependent reactions.
  • ✓

    Built-in Stir Function

    Keeps mixtures homogeneous during stirred cuvette and kinetic assays.
  • ✓

    Nano Hydrophobic Liquid Column Coating

    The coated sample window helps the liquid column form reliably, supporting accurate 1 µL undiluted measurement.
  • ✓

    Cushioned Arm Shock Protection

    The detection arm lowers gently to avoid bubbles that disturb optical density measurement.
  • ✓

    LED Assist Light and Touchscreen

    Guides sample placement and runs standalone from a 7-inch screen, or connects to a PC for reports.

How to Run a Temperature-Controlled Cuvette Assay

  1. Select cuvette mode: Choose cuvette detection on the touchscreen; the mode is selected manually.
  2. Set the temperature: Choose 37°C, 40°C or 45°C and let the cuvette holder reach temperature.
  3. Blank the instrument: Insert a cuvette containing your blank solution and run the blank.
  4. Add the sample: Insert the sample cuvette and switch on stirring if the reaction needs mixing.
  5. Measure: Read a single value, or start the kinetics function to record absorbance over time.

Applications in Biotech & Molecular Diagnostics

  • ✓

    DNA/RNA Quantification Before PCR and NGS

    Check concentration and 260/280, 260/230 purity from 1 µL without dilution. Pair with a Blue-Ray TurboCycler PCR thermal cycler.
  • ✓

    Temperature-Controlled Enzyme Kinetics

    Monitor reactions at 37°C, 40°C or 45°C with stirring and the kinetics function.
  • ✓

    Protein Concentration Analysis

    Direct A280 plus BCA, Bradford and Lowry assays, including incubated colorimetric protocols.
  • ✓

    Cell Density and OD600

    Switch to cuvette mode to track bacterial growth for cloning and protein expression.
  • ✓

    Sample Prep Automation

    Speed up tube handling with the EzDecap automated screw cap decapper.

Institutional Procurement & Laboratory Benefits

Global Bioscience Solutions is an authorized scientific instrument distributor in India. See our guide to scientific instrument suppliers in India or browse all spectrophotometers.

  • ✓

    Cost-Effective Dual Mode Instrument

    Replaces separate microvolume and cuvette spectrophotometers, saving bench space and budget.
  • ✓

    Tenders, GeM and University Purchases

    Suitable for university laboratories and government research facilities, with institutional quotations on request.
  • ✓

    Installation, Training and Warranty

    Local installation, user training and warranty support across India.

Related Products

Frequently Asked Questions

What is the difference between microvolume and cuvette mode?
Microvolume mode reads 1–2 µL directly on the pedestal for fast DNA, RNA and protein quantification without dilution. Cuvette mode uses a standard cuvette and adds heating and stirring, so it suits dilute samples, OD600 and time-course or kinetic assays.
When should I use cuvette mode on a spectrophotometer?
Use cuvette mode for incubated protein assays such as BCA or Lowry, bacterial cell density (OD600), enzyme kinetics, or samples too dilute for microvolume detection.
What is the difference between EzDrop 1000 and EzDrop 1000C?
The EzDrop 1000 is microvolume-only. The EzDrop 1000C adds a cuvette port with built-in heating, stirring and kinetics functions, so one instrument covers both workflows.
What temperatures does the EzDrop 1000C cuvette heater support?
The built-in cuvette heater supports 37°C, 40°C and 45°C, which covers common enzyme and incubation conditions including physiological temperature.
Is the EzDrop 1000C a good NanoDrop alternative with a cuvette?
Yes. It offers 1 µL microvolume sampling over 190–1000 nm like other microvolume instruments, and adds a heated, stirred cuvette port in one compact, touchscreen-operated unit at a more budget-friendly price.
Why use cuvette mode for protein analysis?
Colorimetric assays such as BCA and Lowry need incubation at a set temperature. The 37–45°C control and built-in stirring keep the reaction uniform while it develops, so readings are consistent.
Can the EzDrop 1000C run enzyme kinetics?
Yes. With temperature-controlled, stirred cuvette mode and a kinetics function, you can monitor absorbance over time at a fixed temperature.
How much sample does microvolume mode need?
Only 1 µL to 2 µL per measurement, which preserves precious DNA, RNA and protein samples.
Which assays are built in?
dsDNA, ssDNA, RNA, protein (A280, BCA, Bradford, Lowry) and OD600, with 260/280 and 260/230 purity ratios.
Can the EzDrop 1000C be used without a computer?
Yes. It runs standalone from its 7-inch touchscreen and can also be connected to a computer for report generation.
What is the EzDrop 1000C price in India?
Pricing depends on configuration and quantity. Global Bioscience Solutions, an authorized Blue-Ray Biotech distributor in Bengaluru, provides institutional quotations via the quote form, WhatsApp or sales@globalbiosciencesolution.com.
Do you provide installation, training and warranty in India?
Yes. GBS provides installation, user training and warranty support for the EzDrop 1000C across India.

Request Quotation

Get the official EzDrop 1000C price list within 30 minutes.


WhatsApp Sales Support
Global Bioscience Solutions
2111, 2nd Cross Rd, D-Block, Gayatrinagar, Rajajinagar, Bengaluru, Karnataka 560021
+91 97436 20456
sales@globalbiosciencesolution.com